Call us now (021) - 22570798

KYORITSU


6315-01 Power Quality Analyzer (500A)

Wiring connections=1P2W, 1P3W, 3P3W, 3P4WVoltage Range=600.0 / 1000VAccuracy=±0.2%rdg±0.2%f.s. (sine wave, 40 - 70Hz)Sampling speed of Voltage transient=24µsCurrent Range 8128=( 50A type ) : 5000mA / ..

IDR93,280,000.00IDR Ex Tax: IDR93,280,000.00IDR

AC Digital Clamp meter KEW 2210R

AC A (RMS)= 30.00/300.0/3000AConductor size= φ150mm max.Influence of Conductor position= Additional ±3% (max.) depending on the             ..

IDR6,930,000.00IDR Ex Tax: IDR6,930,000.00IDR

AC/DC Digital Clamp Meters KEW 2046R

AC A (RMS)= 0 - 600.0A                          ±2.0%rdg±5dgt (50/60Hz)&nbs..

IDR5,394,400.00IDR Ex Tax: IDR5,394,400.00IDR

AC/DC Digital Clamp Meters KEW 2056R

AC A (RMS)= 0 - 600.0A                          ±2.0%rdg±5dgt (50/60Hz)&nbs..

IDR5,665,000.00IDR Ex Tax: IDR5,665,000.00IDR

Analog Insulation Tester 3123A

DC test voltage=5000VMeasuring ranges=5GΩ/200GΩ First effective measuring ranges=0.2 ~ 100GΩAccuracy=|± 5% rdgOther ranges accuracy=|±10% rdg or 0.5% of scale lengthWithstand voltage=5000V AC for..

IDR18,480,000.00IDR Ex Tax: IDR18,480,000.00IDR

Analog Multitester Multimeter Analog Kyoritsu KEW 1109S

DC V= 0.1/0.5/2.5/10/50/250/1000V             ±3% of FS (20kΩ/V)AC V= 10/50/250/1000V (9kΩ/V)             ±3% of FSDC A= 50µA/2.5/..

IDR1,540,000.00IDR Ex Tax: IDR1,540,000.00IDR

Analogue Clamp Meter MODEL 2608A

AC A= 6/15/60/150/300A ±3% of FSAC V=  150/300/600V ±3% of FSDC V= 60V ±3% of FSΩ= 1/10kΩ (25/250Ω mid-scale)Conductor size= Ø33mm max.Frequency response=  50Hz/60Hz Power source= R6 (AA) (1..

IDR1,815,000.00IDR Ex Tax: IDR1,815,000.00IDR

Analogue Insulation MODEL 3166

DC Test Voltage= 1000VMax. effective scale value= 2000MΩMid-scale value= 50MΩFirst effective measuring range= 2 - 1000MΩAccuracy= ±5% rdgSecond effective measuring ranges= 1/2000MΩAC Voltage= 600VIncl..

IDR3,630,000.00IDR Ex Tax: IDR3,630,000.00IDR

Analogue Insulation KEW 3431

 Test voltage= 250V/500V/1000VMax. effective scale value= 200MΩ/2000MΩMid-scale value= 5MΩ/50MΩFirst effective measuring ranges= 0.1MΩ - 100MΩ  1MΩ - 1000MΩAccuracy= ±5% of indicated valueSe..

IDR8,910,000.00IDR Ex Tax: IDR8,910,000.00IDR

Analogue Insulation MODEL 3131A

Test voltage= 250V/500V/1000VMeasuring ranges (Mid-scale value)= 100MΩ/200MΩ/400MΩ                   &nbs..

IDR5,423,000.00IDR Ex Tax: IDR5,423,000.00IDR

Analogue Insulation Testers MODEL 3161A

DC Test Voltage= 15V/500VMax. effective scale value= 20MΩ/100MΩMid-scale value= 0.05MΩ/2MΩFirst effective measuring range= 0.005 - 2MΩ/           ..

IDR7,403,000.00IDR Ex Tax: IDR7,403,000.00IDR

Analogue Insulation Testers MODEL 3165

DC Test Voltage= 500VMax. effective scale value= 1000MΩMid-scale value= 20MΩFirst effective measuring range= 1 - 500MΩAccuracy= ±5% rdgSecond effective measuring ranges= 0.5/1000MΩAC voltage range= 60..

IDR3,410,000.00IDR Ex Tax: IDR3,410,000.00IDR

Analogue Multimeters MODEL 1110

DC V= 0.3V (16.7kΩ/V) ±3% of FS             3/12/30/120/300/600V (20kΩ/V)           &..

IDR2,266,000.00IDR Ex Tax: IDR2,266,000.00IDR

Case MODEL 9132

• Carrying case with magnet• Easy-to-use setting with magnet on the steel plate etc. of switch board• 188 (L) × 136 (W) × 77 (D)mm..

IDR2,750,000.00IDR Ex Tax: IDR2,750,000.00IDR

CLAMP METER KEW 2002R

AC A= 400A (0 - 400A)             ±1.5%rdg±3dgt [45 - 65Hz]             ±2.5%rdg±3dgt [40Hz - 1kHz]        &nb..

IDR4,950,000.00IDR Ex Tax: IDR4,950,000.00IDR

Showing 16 to 30 of 110 (8 Pages)